Latitude EV is the only total elbow implant that is designed to replicate the natural anatomy of the elbow. The innovative Latitude gives surgeons the ability to reproduce the natural flexion/extension axis and restore natural kinematics of the elbow with its anatomic design. The Latitude EV implant design is founded on the original Latitude implant which has been in clinical use since 2001.
Latitude EV Total Elbow prosthesis is designed to reproduce the patient’s anatomy and restore the natural kinematics of the elbow, while offering maximum flexibility in elbow arthroplasty.
Design Feature |
Advantage |
Intraoperative flexibility to link or unlink the implant (a change in linkage can be performed at any time) |
Flexible options to address a wide range of indications and patient needs |
Linked ulnohumeral components can accommodate the native radial head or the Latitude EV bipolar radial head |
Allows for optimal mechanical balance of radiohumeral articulation |
Ti Plasma Spray |
Enhances long term fixation |
Humeral Spool
Concave barrel shaped trochlea preserves linear contact through 7° varus/valgus movement with ulnar component
Radial Head Option
60% of comprehensive loads are transferred across the radiohumeral joint. Morrey et al, JBJS 70-A 1988. Latitude is the only total elbow prosthesis that enables surgeons to maintain the radiohumeral joint when alignment is adequate.
Ulnar Stem
Shape replicates natural bow of the ulna to aid in ease of insertion and reduce stresses on the cortical wall
Humeral Stem
Square shape for rotational stability
Anterior Flange
For bone graft
Medial/Lateral Fins
Prevent rotation
Ulnar Cap Option
To enable use as a linked or unlinked implant
The Latitude EV system offers new, completely redesigned instrumentation. The instrumentation system allows for accurate component positioning with humeral, ulnar, and radial preparations that are separate but codependent.
The Tornier Elbow Prosthesis is intended for total elbow arthroplasty. Prosthetic replacement with this device may be indicated to relieve severe pain or significant disability following the effects of primary or secondary osteoarthritis and rheumatoid arthritis; correction of functional deformities; revision procedures where other treatments or devices have failed; treatment of fractures that are unmanageable using other techniques. The Tornier Elbow Prosthesis is intended for cemented use only.
Systemic infection is an absolute contraindication. Every effort should be made to rule out the possibility of preoperative sepsis in patients who have one or more of the following abnormalities: fever and/or local inflammation; rapid joint destruction or bone resorption apparent on roentgenograms; elevation of sedimentation rate unexplained by other disease; elevation of WBC count; distant foci of infection from genitourinary, pulmonary, skin and other sites, dental focus infection which may cause hematogenous spread to the implant site; skeletally immature patients; cases where there is inadequate neuromuscular status, poor bone stock, or poor skin coverage around the elbow joint that would make the procedure unjustifiable; neuromuscular or psychiatric disorders which might jeopardize fixation and postoperative care; known allergy to one of the materials; pregnancy.
Graham King, MD (University of Western Ontario); Shawn O’Driscoll, MD, PhD (Mayo Foundation); Ken Yamaguchi, MD (Washington University)
| Humeral Spools | |
| DKY211 | Small Right |
| DKY212 | Small Left |
| DKY213 | Medium Right |
| DKY214 | Medium Left |
| DKY215 | Large Right |
| DKY216 | Large Left |
| DKY217 | Large+ Right |
| DKY218 | Large+ Left |
| Humeral Stems | |
| 0030302 | Small Standard Right |
| 0030303 | Small Standard Left |
| 0030402 | Medium Standard Right |
| 0030403 | Medium Standard Left |
| 0030502 | Large Standard Right |
| 0030503 | Large Standard Left |
| 0030312 | Small 150 mm Right |
| 0030313 | Small 150 mm Left |
| 0030412 | Medium 150 mm Right |
| 0030413 | Medium 150 mm Left |
| 0030512 | Large 150 mm Right |
| 0030513 | Large 150 mm Left |
| 0030322 | Small 200 mm Right |
| 0030323 | Small 200 mm Left |
| 0030422 | Medium 200 mm Right |
| 0030423 | Medium 200 mm Left |
| 0030522 | Large 200 mm Right |
| 0030523 | Large 200 mm Left |
| Ulnar Stems | |
| 0030010 | Small Short Right |
| 0030011 | Small Short Left |
| 0030110 | Medium Short Right |
| 0030111 | Medium Short Left |
| 0030210 | Large Short Right |
| 0030211 | Large Short Left |
| 0030020 | Small Standard Right |
| 0030021 | Small Standard Left |
| 0030120 | Medium Standard Right |
| 0030121 | Medium Standard Left |
| 0030220 | Large Standard Right |
| 0030221 | Large Standard Left |
| 0030030 | Small 125 mm Right |
| 0030031 | Small 125 mm Left |
| 0030130 | Medium 125 mm Right |
| 0030131 | Medium 125 mm Left |
| 0030230 | Large 125 mm Right |
| 0030231 | Large 125 mm Left |
| 0030040 | Small 150 mm Right |
| 0030041 | Small 150 mm Left |
| 0030140 | Medium 150 mm Right |
| 0030141 | Medium 150 mm Left |
| 0030240 | Large 150 mm Right |
| 0030241 | Large 150 mm Left |
| Ulnar Caps | |
| DKY067 | Small |
| DKY068 | Medium |
| DKY069 | Large |
| Radial Heads and Stems | |
| DKY056 | Small Head |
| DKY057 | Medium Head |
| DKY058 | Large Head |
| DKY059 | Large+ Head |
| DKY061 | 5.0 mm Stem |
| DKY062 | 6.5 mm Stem |
| Cement Restrictors | |
| EBO101 | Cement Restrictor (Diameter Range 8-15 mm) |
| EBO102 | Cement Restrictor (Diameter Range 5-8 mm) |
| Single Use Items | |
| DKY090 | Single Use Suture Passer |
| DWD060 | 3 mm Drill Bit |